Category Archives: HVAC

Transformer

Pricing Subject to Change. Transformer

Central Air Conditioner Evaporator Service Coil Assembly

This evaporator service coil assembly (part number P140124) is for central air conditioners.Evaporator coil P140124 transfers heat from the refrigerant to the air blowing across the evaporator.A service technician should do this repair because it involves recovering and recharging refrigerant in the sealed refrigerant system.

Furnace Blower Fan Motor

This blower fan motor (part number 58MV660004) is for furnaces.Blower fan motor 58MV660004 circulates the air through the heating chamber and out into the room.Shut off the electrical power supply to the furnace before installing this part. Wear work gloves to protect your hands.

Central Air Conditioner Air Handler Blower Motor

This air handler blower motor (part number HC33AE208) is for central air conditioners.Air handler blower motor HC33AE208 circulates air into the room.Shut off the circuit breaker to the air conditioner before installing this part. Wear work gloves to protect your hands.

Grommet

Pricing Subject to Change. Grommet

Central Air Conditioner Heat Pump Defrost Control

This heat pump defrost control (part number 1173637) is for central air conditioners.Heat pump defrost control 1173637 monitors the temperature of the heat pump coils and signals the control board to start or stop the defrost cycle.Shut off the circuit breaker to the air conditioner condensing unit before installing this part. Wear work gloves to

Spring Clip

Pricing Subject to Change. Spring Clip

Furnace Intermittent Pilot Ignition Control Module

This intermittent pilot ignition control module (part number B1370724) is for furnaces.Intermittent pilot ignition control module B1370724 controls the spark for lighting the burner flame.Shut off the electrical power supply to the furnace before installing this part. Wear work gloves to protect your hands.

Time Delay

Pricing Subject to Change. Time Delay

Furnace Fan Control Board

This fan control board (part number 1014459) is for furnaces.Fan control board 1014459 manages the fan functions and heat delay settings of the furnace.Shut off the electrical power supply to the furnace before installing this part. Wear work gloves to protect your hands.

Blower

Pricing Subject to Change. Blower

Central Air Conditioner Condenser Fan Motor, 1/6-HP

This condenser fan motor (part number 1052662) is for central air conditioners.Condenser fan motor 1052662 spins the fan blade that cools the refrigerant in the condenser. The motor is a single-speed 1,100-RPM motor with a 1-3/4-inch shaft.Shut off the circuit breaker to the air conditioner condensing unit before installing this part. Wear work gloves to

Furnace Inducer Vent Motor Assembly

This inducer vent motor assembly (part number 1014529) is for furnaces.Inducer vent motor assembly 1014529 removes fumes from the combustion chamber and blows them into the exhaust vent system.Shut off the electrical power supply to the furnace before installing this part. Wear work gloves to protect your hands.

Furnace Air Pressure Switch

This air pressure switch (part number 1014827) is for furnaces.Air pressure switch 1014827 detects airflow through the furnace.Disconnect electrical power before installing this part. Wear work gloves to protect your hands.

Furnace Inducer Vent Gasket

This inducer vent gasket (part number 1012588) is for furnaces.Inducer vent gasket 1012588 seals the opening for the inducer vent to prevent air leaks.Shut off the electrical power supply to the furnace before installing this part. Wear work gloves to protect your hands.

Furnace Blower Fan Motor, 1/2-HP

This blower fan motor (part number 1013341) is for furnaces.Blower fan motor 1013341 circulates the air through the heating chamber and out into the room. Motor specifications: 4-speed, 3-1/2-inch shaft, 1,050-RPM and counterclockwise rotation.Shut off the electrical power supply to the furnace before installing this part. Wear work gloves to protect your hands.

Drain Trap

Pricing Subject to Change. Drain Trap

Furnace Burner Roll-Out Limit Switch

This burner roll-out limit switch (part number 1013104) is for furnaces.Burner roll-out limit switch 1013104 detects when the flame flares out the front of the burner box and shuts down the burner to prevent overheating.A service technician should examine the furnace for potential problems and install this part.

Furnace Temperature Limit Switch

This temperature limit switch (part number 1013105) is for furnaces.Temperature limit switch 1013105 turns off the burner or element if the furnace overheats.Shut off the house circuit breaker for the furnace before installing this part.

Furnace Gas Valve

This gas valve (part number 1013351) is for furnaces.Gas valve 1013351 controls the gas supplied to the burner in the furnace.Disconnect electrical power and shut off the gas supply before installing this part. Wear work gloves to protect your hands.